LEVEL INDICATOR / TRANSMITTER FOR LIQUIDS
HIGH PRESSURE AND TEMPERATURE
TECFLUID LT
Range: 1/2 “to DN100
Accuracy: ± 10 mm
Maximum temperature: 400ºC.

LEVEL INDICATOR / TRANSMITTER FOR LIQUIDS
HIGH PRESSURE AND TEMPERATURE
TECFLUID LT
Range: 1/2 “to DN100
Accuracy: ± 10 mm
Maximum temperature: 400ºC.
Principle of operation
METER WITH FLOAT / ROD SUITABLE FOR HIGH PRESSURE / TEMPERATURE – TECFLUID LT
According to the principle of communicating vessels. A float immersed in a chamber that communicates with the tank whose liquid level is to be measured, floats on the surface of said liquid and moves with it, as the level increases or decreases.
The float is designed for the specific density of the operating liquid and indicates the level of the tank by magnetic transmission through an external magnetic tracker or magnetic sheets (depending on the model) mounted externally to the chamber and isolated from it. p >

Features
METER WITH FLOAT/ROD SUITABLE FOR HIGH PRESSURE/TEMPERATURE – TECFLUID LT
Accuracy:
± 10 mm
Materials:
Parts in contact with the fluid in AISI 316L, PVC, PP, PTFE, PVDF, titanium, hastelloy C
Types of connection:
Flange, thread, sanitary connection
Sizes and flow rates:
Depending on the model, from 1/2″ to DN100
Maximum temperature:
400ºC
Maximum pressure:
Depending on the model, PN100 to PN10
Accessories:
- Automation
- Transmitter (ATEX / IECEx certification and optional HART, Profibus, Fieldbus, Modbus RTU RS 485 protocols
- Thermal separator
- Indicator box AISI 316L or in PP
- Converter with remote display
- Double heating chamber – Cooling
- Ex d certificate
Applications
METER WITH FLOAT / ROD SUITABLE FOR HIGH PRESSURE / TEMPERATURE – TECFLUID LT
- Chemical, petrochemical industry
- Process industry
- Thermal and refrigeration installations
- Naval industry
- Boilers
- Storage parks