GLASS TUBE FLOW METER
FLANGES / THREAD
TECFLUID 6000
Range: 1/2 “- 3”
Accuracy: 1.6% (qG = 50%)
Maximum temperature: 80ºC.

GLASS TUBE FLOW DISPLAYER
FLANGES / THREAD
TECFLUID 6000
Range: 1/2 “- 3”
Accuracy: 1.6% (qG = 50%)
Maximum temperature: 80ºC.
Principle of operation
FLOW METER GLASS TUBE – TECFLUID 6000
The 6000 Tecfluid Series flow meters work according to the variable area principle, obtained by a float that moves inside a conical tube. borosilicate glass . The circulating flow moves to the float, up to a height inside the conical tube, where the forces are balanced: – E = fluid thrust – Pf = float weight – Al = free area of passage (Al = Ac, area tube – Af, float area). Each float height or position corresponds to a value of the circulating flow.

Features
FLOW METER GLASS TUBE – TECFLUID 6000
Accuracy:
1,6% (qG=50%)
Materials:
- Borosilicate glass tube. Parts in contact with the fluid in steel, AISI316L, PP, PVC and PTFE
- Floats in AISI316L, aluminum, PTFE, PVDF-Pb, PVC-Pb, PTFE-Pb, titanium
Connection types:
Flange, thread, smooth in PVC for gluing and AISI 316, PP for welding and clamp
Sizes and flow rates:
- From 1/2 “to 3”
- From 2.5 l / h to 50 m3 / h H2O 20ºC
Maximum temperature:
80ºC
Maximum pressure:
Depending on the size of the meter, from 15 to 5 bar
Accessories:
- Automation
- Transmitter (ATEX certification and optional HART, PROFIBUS, FIELDBUS protocols.
Applications
FLOW METER GLASS TUBE – TECFLUID 6000
- Water treatment
- Heating and cooling flow control
- Research laboratories
- Gas burner control
- Chemical industries and heat treatment furnaces
- Test benches