Flanged globe valves
VÁLVULAS INDUSTRIALES
VÁLVULAS INDUSTRIALES
Flanged globe valves bolt to the pipe and can be removed without cutting the line. They are the usual design for process, steam and hot water service from DN15 upwards. GRM supplies KTN, ARI and KSB models with DIN EN 1092 PN16/40 and ANSI ASME B16.5 Class 150 to 1500 flanges, from DN15 to DN500, with bellows sealed versions for fluids that must not escape.
| Quick facts | GRM flanged globe valves |
|---|---|
| Flanges | EN 1092 PN10, PN16 and PN40; ASME B16.5 Class 150 to 1500 |
| Sizes | DN15 to DN500 |
| Body | WCB cast steel, CF8M stainless steel, A105 forged steel, carbon steel, grey and ductile iron |
| Seat | Stellite or metal; EPDM plug for drinking water |
| Temperature | −60 ºC to +420 ºC depending on model |
| Options | Bellows seal, regulating plug, straight, angle or Y pattern |
Flanged globe valve models
| Model | Flanges | Sizes | Pressure | Features |
|---|---|---|---|---|
| KTN 431/433 | ANSI B16.5 | DN50 to DN500 | Class 150 to 1500 | WCB steel or CF8M stainless; ASME B16.34 design |
| KTN 434 | ANSI B16.5 | DN50 to DN500 | Class 150 to 1500 | A105 forged steel, stellited seat, API 602; up to +420 ºC |
| KTN 423f | EN 1092 PN16 | DN15 to DN200 | PN16 | Bellows seal, vacuum service; −20 ºC to +350 ºC |
| ARI FABA Plus | EN 1092 | DN15 to DN300 | PN16/40 | Bellows seal; straight, angle or Y pattern; −60 ºC to +400 ºC |
| KSB BOA | EN 1092 | DN15 to DN200 | PN10/16 | Drinking water (DVGW) and HVAC; up to +80 ºC |
ANSI flanges for process service
The KTN 431/433 covers DN50 to DN500 in Class 150 to 1500, with WCB cast steel (431) or CF8M stainless steel (433) body and pressure-temperature ratings to ASME B16.34. The KTN 434 is the A105 forged steel version with stellite hardened seat, designed to API 602. Both are suitable for water, steam, oil and gas.
Bellows sealed DIN valves for steam and thermal oil
The KTN 423f has a bellows that seals the stem and graphite spiral wound gaskets. It works from −20 ºC to +350 ºC at PN16 and suits vacuum, seawater, steam and thermal oil. The ARI FABA Plus reaches DN300 and PN40, works from −60 ºC to +400 ºC and accepts regulating, PTFE or balanced plugs. It is used for steam, district heating, thermal oil, ammonia and vacuum service.
DIN flanged valves for drinking water
The KSB BOA has internal and external epoxy coating, an inclined seat and an EPDM plug with DVGW drinking water approval. It isolates and regulates, includes a position indicator and lock, and works up to +80 ºC at PN10/16. It is common in HVAC, cooling circuits and water supply.
How to choose a flanged globe valve
- Flange standard: PN for DIN, class for ANSI. See the differences between DIN and ANSI standards.
- Fluid: bellows seal for steam, thermal oil, vacuum or hazardous fluids; EPDM for drinking water.
- Pressure and temperature: PN16/40 for DIN; up to Class 1500 for ANSI.
- Size: if your drawings are in inches, use the DN to inches table.
For small sizes, compare with our threaded globe valves and weld end globe valves. For the rest of the range, go back to the globe valves family.
Frequently asked questions
Which flanged globe valve should I use for steam?
For steam, a bellows sealed globe valve is advisable, as it eliminates stem leakage. We supply the KTN 423f (PN16, up to +350 ºC) and the ARI FABA Plus (PN16/40, up to +400 ºC). With ANSI flanges, the forged steel KTN 434 reaches +420 ºC.
What pressure can flanged globe valves handle?
For DIN, up to PN40 with the ARI FABA Plus. For ANSI, up to Class 1500 with the KTN 431/433 and KTN 434.
Are there flanged globe valves for drinking water?
Yes. The KSB BOA has epoxy coating and an EPDM plug with DVGW drinking water approval, at PN10/16 and up to DN200.
Request a quote for flanged globe valves
Tell us the size, flange standard and pressure, temperature, fluid and whether you need a bellows seal. Contact GRM. Phone (Barcelona) +34 93 587 22 22, Madrid +34 91 685 25 15, WhatsApp +34 628 512 590 and email grm@grmindustrial.es, 8:00 to 19:00 (CET).